Eppendorf Reference Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Eppendorf Reference. Eppendorf Reference User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Eppendorf Reference
Operating Manual
®
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Eppendorf Reference

Eppendorf ReferenceOperating Manual ®

Page 2 - Eppendorf Reference®

95.1 Reference fix5.2 Reference variableModel /VolumeColorcodeepT.I.P.S. SystematicerrorRandomerrorμL μL%μL%μL12510102025501002002505001,0001,5002,000

Page 3

10The technical data is only valid when the quoted eppendorf pipette tips are used.Tests carried out in accordance with ISO 8655 for piston-stroke pip

Page 4

11The pipette can be individually labelled. The autoclavable blank adhesive label provided can be marked with a permanent marker and fits onto the ide

Page 5 - Operating Manual

127.4 Dispensing liquid– Hold the tip at an angle against the inside wall of the tube.– Press down the control button slowly to the first stop (measur

Page 6

13The serial number of the pipette is located on its control button.8.1 TestingDistilled water is dispensed from a pre-wetted tip into a tube and is t

Page 7

14If the place where the pipette is used is at extremely high altitude, an adjustment must be made in line with the ambient air pressure. At 1,000 m a

Page 8 - 3 General safety notes

15e Adjust control button by the volume determined.One revolution of the control button corresponds to the following values for water:Clockwise rotati

Page 9

16d Pierce the calibration seal attached to the openingfor adjustments with Side B of the key provided.This destroys the seal which should be removed.

Page 10 - 5 Technical data

179.1 CareDepending on the frequency of use, all parts of the pipette should be cleaned from time to time in a soap solution or should be carefully wi

Page 11

189.3 Decontamination prior to dispatchIf the Reference pipette is to be checked, repaired or calibrated by Eppendorf AG or another service partner, i

Page 12

1Reference variabel / Reference adjustable0.1 – 2.5 μL0.5 – 10 μL2–20μL10–100 μL 20–200 μL 100 – 1000 μL 500 – 2500 μLReference fix1–50μL 100 μL 200 –

Page 13

19Error Cause SolutionDroplets onthe inner wallof the pipette tip.– Uneven wetting of the plastic wall.– A pipette tip with poor wetting properties ha

Page 14

20Control button jams, moves erratically.– Piston contaminated.– Seals contaminated.– Penetration of solvent vapors.– Clean piston and lubricate light

Page 15

2110.1 If there is doubt that dispensing data are correctTo avoid dispensing errors, the precision and accuracy of the Reference pipettes need to be c

Page 16

94MaintenanceI Exchanging the piston ...95II Exchanging the seals ...

Page 17

95Eppendorf Reference® – Part B – Maintenance– Unscrew pipette at the central junction.– Press control button and hold down. Hold piston at the top of

Page 18

96Removing the sealsFig. 2 – 6 on the following pages show you how to remove the seals. The numbers shown are identical with the numbers in the Orderi

Page 19

9710 – 100 μL ( Fig. 3)Push the control button all the way down and pull off the ejector sleeve (13).Piston seal (4)– Unscrew pipette.– Discard seal (

Page 20

9850 – 200 μL ( Fig. 4)Push the control button all the way down and pull off the ejector sleeve (13).Piston seal (4)– Unscrew pipette.– Remove piston

Page 21

9950 – 250 μL ( Fig. 5)Push the control button all the way down and pull off the ejector sleeve (13).Piston seal (4)– Unscrew pipette at the central j

Page 22

100100 – 1000 and 500 – 2500 μL (Fig. 6)Push the control button all the way down and pull off the ejector sleeve (13).Piston seal (4)– Unscrew pipette

Page 23 - Maintenance

2 Operating Manual ...4 Bedienungsanleitung ...

Page 24

101Inserting the sealsPull new seal off the pin and push screw, spring, seal (with plastic part first) in that order onto side B of the wrench as show

Page 25

102Ordering Information(Please see page 1 (Fig. 1) of this manual).Only parts with order numbers are available separately.Pipettes / spare partsModels

Page 26

103Order numberInternationalOrder numberNorth America1Piston1 – 10 μL (gray control button) 4910 810.001 02247508820 μL 4910 811.00810 – 20 μL (yellow

Page 27

104Order numberInternationalOrder numberNorth America5 Lower housing not sold separately6 Ejector, includes ejector spring (7)1 – 20 μL, incl. ejector

Page 28

105Order numberInternationalOrder numberNorth America13 Ejector sleeve1–100 μL4910 845.000 022475827150 – 200 μL 022475843200 – 1000 μL 4910 846.00625

Page 29

106(Please see page 1 (Fig. 1) of this manual).Only parts with order numbers are available separately.Pipettes / spare partsModels Order numberInterna

Page 30

107Order numberInternationalOrder numberNorth America4 Piston seal10–100 μL, incl. screw (8), spring (9) 4910 820.007 02247528250–200 μL, with 2 O-r

Page 31 - Ordering Information

108Order numberInternationalOrder numberNorth America12 Filling tube, (5 pieces, 1 wire punch)10–100 μL 4910 837.007 02247574650–200 μL, incl. 2 piece

Page 32

109Order numberInternationalOrder numberNorth AmericaPipette carousel, incl. 6 pipette supports 3115 000.003 022444905Pipette holder (replacement for

Page 33

110epT.I.P.S.(The packaging units stated represent the minimum ordering quantity).Length Color code Order numberInternationalOrder numberNorth America

Page 35

111Length Color code Order numberInternationalOrder numberNorth AmericaBox, 1 box plus 96 tips0.1 – 10 μL 34 mm dark gray 0030 073.002 0224913000.1 –

Page 36

112Length Color codeOrder numberInternationalOrder numberNorth AmericaSingles (Eppendorf Biopur), colorless, pyrogen-free, DNA-free, RNase-free, ATP-f

Page 37

113Length ColorcodeOrder numberInternationalOrder numberNorth AmericaReloads, LoRetention PCR clean, 10 x 96 = 960 tips0.1 – 10 μL 34 mm dark gray 003

Page 38

AUSTRALIA & NEW ZEALANDEppendorf South Pacific Pty. Ltd.Phone: +61 2 9889 5000Fax: +61 2 9889 5111E-mail: [email protected]: www.eppen

Page 39

Your local distributor: www.eppendorf.com/worldwideEppendorf AG · 22331 Hamburg · Germany · Tel: +49 40 538 01-0 · Fax: +49 40 538 01-556 · E-Mail: ep

Page 40

4Eppendorf Reference® – Part A – Table of contentsOperating Manual1 Main Illustration ...

Page 41

51Control button The control button is for setting the volume, dispens-ing and ejecting the pipette tip.2Volume display Displays the preset volume. 3L

Page 42

62.1 Hazard icons2.2 Danger levelsThe danger level is part of a safety note and defines the potential consequences if the information contained therei

Page 43 - Eppendorf Offices

7WARNINGWARNING! Damage to health due to handling infectious liquids and pathogenic germs. Observe the national regulations for handling these substa

Page 44 - is a registered trademark

8NOTICENOTICE! Damage to device from missing pipette tips. Only use the Reference with attached pipette tips. NOTICENOTICE! Carry-over, contamination

Commentaires sur ces manuels

Pas de commentaire