Eppendorf BioSpectrometer® basic — Supplementary Information
Supplementary Information
Eppendorf BioSpectrometer® basicseeon p.Fig.Tab .p.
Leaflet
Changes in the operating manual
Changes in the operating manual
This supplementary sheet is a supplement to the operating manual for the BioSpectrometer basic and not a
substitute. Therefore, also read the operating manual of the BioSpectrometer before using the
BioSpectrometer for the first time. The current version of the operating manual is available on the internet at
www.eppendorf.com
1.2.1 Hazard icons
2.1 Main illustration
The location of the name plate deviates from the main illustration. It is located on the bottom of the device on
the rear left.
2.3.5 Device self-check
The factory setting for the self-test interval has been adjusted to "weekly".
During the self-test, ensure that the following requirements are met:
Observe the ambient conditions (chapter 11.2).
Avoid temperature fluctuations (for example, caused by open windows).
After the device has been transported from a cool to a warmer environment, condensation can form
inside the device. Wait at least three hours before connecting the device to the power supply.
Make sure that the cuvette shaft is clean.
4.4/4.5 Connecting a printer/PC
Only connect devices that meet the safety requirements defined in IEC 60950-1.
5.3.2 Measurement procedure and 6.4.7 print & export
Method step print & export
In the print & export method step the [Sample] softkey is active in the display.
If you want to select sample results for export or printout, press the [Sample] softkey.
6.2.2 Routine method group
Proteins direct UV: 2 additional methods
Nucleic acids: 1 additional method
Caution, general hazard point, observe the operating manual.
Protein A 280
Evaluation using factor = 1
Absorbance values are displayed directly as a result.
Protein A 280 1 mm
Parameter Cuvette = 1 mm
For microliter cuvettes with a light path of 1 mm, e.g., Hellma
®
TrayCell or
microliter cuvettes of a similar design.
dsDNA 1 mm
Parameter Cuvette = 1 mm
For microliter cuvettes with a light path of 1 mm, e.g., Hellma
®
TrayCell or
microliter cuvettes of a similar design.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Supplementary Information

Eppendorf BioSpectrometer® basic — Supplementary InformationSupplementary Information — Eppendorf BioSpectrometer® basicseeon p.Fig.Tab .p.Leafle

Page 2

Eppendorf BioSpectrometer® basic — Supplementary Information11.1 Technical data: power supply11.2 Technical data: ambient conditionsPower supply 100